What does the KS-OFCT-50 test?
Optical fiber cable in tensile loading (IEC 60794-1-2 Method E1) and crush (Method E3). A 150 m sample runs in six 25 m legs over sheaves, with spliced fibers led to OTDR and strain instrumentation.
Which standards apply?
Load is verified to ISO 7500-1, EN 10002-2, ASTM E4 and JIS B7721 at ±0.5% of reading; strain channels follow ASTM E83, ISO 9513 and EN 10002-4.
How is pass or fail judged?
Attenuation change typically stays within 0.05 dB and elongation under installation load within 0.25%. In E3 the reading is taken after a 10-minute hold and again five minutes after release, with no fracture or cracking of cable elements.
What capacity and control are offered?
50 kN capacity, 0.2–500 mm/min loading, a 100 x 100 mm compression head at HB 240–280, 800–1100 mm crosshead travel and Panasonic servo positioning to 0.004 mm.
How accurate is elongation measurement?
A 1000 mm gauge length resolves better than 10 microns at ±0.5% accuracy, with ±0.3% displacement accuracy.
How Does the KS-OFCT-50 Test Optical Fiber Cable to IEC 60794-1-2 E1 and E3?